TSI インターフェース

現在、このページはご希望の言語でご利用いただけません。 Google 翻訳を使用すると自動翻訳でページを表示できます。 弊社はこのサービスの提供に責任を持たず、翻訳結果を弊社でチェックすることはありません。
さらにサポートをご希望の場合は、弊社までお問い合わせください。

ページコンテンツダウンロード各国事務所へのお問い合わせ オンラインでのお問い合わせ

TSI 3Interfaces for tool setting arms and probes for turning centres.

Tool setting interface options

 

TSI 2   TSI 3   TSI 2-C   TSI 3-C
TSI 2 interfaceUse with HPRA, HPPA   TSI 3 interfaceUse with HPMA, HPGA  
TSI 2-C
Use with HPRA, HPPA
 
TSI 3-C
Use with HPMA
TSI 2 can be DIN rail mounted within the machine control cabinet.   TSI 3 units are DIN rail-mounted and feature an 'Easy fit' location mechanism.   As  the TSI 2 but with Solid state relay (SSR) output for easier user configuration.   As  the TSI 3 but with Solid state relay (SSR) output for easier user configuration.

TSI 2 specification

Specification  
Principal application Hard-wired probing systems with HPRA and HPPA
Mounting DIN rail mounting
Outputs 1. Probe status (no complement)
2. Position confirm signals (machine ready and arm ready)
Output signal format 1. Unipolar active high probe status outputs (non configurable)
2. Unipolar active high confirm outputs for machine ready and arm ready positions (non configurable)
Other I/O Can be connected to either a standard single wire probe input or the four wire alternative.
Select any one output for single wire probe input or utilise all four inputs/outputs for four wire probe inputs.
Power supply 18 V - 30 V dc, Imax = 50 mA not including output loading.
Fuse protected at 250 mA (FF)
TTL compatibility Not compatible
Inputs 1. Inhibit
2. Probe select inputs
Input signal format 1. Internally pulled down (2k4) ACTIVE HIGH
2. Internally pulled down (2k4) ACTIVE HIGH
Probe vibration filter A trigger delay circuit (6.5 ms) can be activated by reversing the brown and white wire connections to the TSI 2 (PL2-1 and PL2-3)

TSI 3 specification

Specification  
Principal application Hard-wired probing systems with HPMA and HPGA.
Mounting DIN rail mounting
Outputs 1. Probe status (no complement)
2. Position confirm signals (machine ready and arm ready)
Output signal format 1. Unipolar active high probe status outputs (non configurable)
2. Unipolar active high confirm outputs for machine ready and arm ready positions (non configurable)
Other I/O Can be connected to either a standard single wire probe input or the four wire alternative.
Select any one output for single wire probe input or utilise all four inputs/outputs for four wire probe inputs.
Power supply

Interface voltage supply (1, 13, 25) 18 V - 30 V dc, Imax = 100 mA not including output loading.
Motor voltage supply (10, 22, 11, 23) 24 V dc + 20% - 10%, Imax + 2.5 A for 4 s (worst case stall). Overcurrent and reverse connection protected.
Self-resettable

TTL compatibility Not compatible
Inputs 1. Inhibit, Arm ready, Machine ready
2. Probe Select inputs2. Probe select inputs
Input signal format 1. Internally pulled down (2k4) ACTIVE HIGH
2. Internally pulled down (2k4) ACTIVE HIGH
Probe vibration filter A trigger delay circuit (6.5ms) can be activated by reversing the brown and white wire connections to the TSI 3 (PL2-1 and PL2-3)

TSI 2-C specification

Specification  
Principal application Hard-wired probing systems with HPRA and HPPA
Mounting DIN rail mounting
Outputs 1. Probe status (N/O or N/C)
2. Position confirm signals (machine ready and arm ready)
Output signal format - voltage free SSR

Probe status N/C or N/O, MRO and  ARO N/O

Maximum current 40 mA

Maximum voltage 30 V

Outputs are protected by fuses (TE5) (f) 50mA

Other I/O Can be connected to either a standard single wire probe input or the four wire alternative.
Select any one output for single wire probe input or utilise all four inputs/outputs for four wire probe inputs.
Power supply 18 V - 30 V dc, Imax = 50 mA not including output loading.
Fuse protected at 250 mA (FF)
TTL compatibility Not compatible
Inputs 1. Inhibit
2. Probe select inputs
Input signal format 1. Internally pulled down (2k4) ACTIVE HIGH
2. Internally pulled down (2k4) ACTIVE HIGH
Probe vibration filter A trigger delay circuit (6.5 ms) can be activated by reversing the brown and white wire connections to the TSI 2 (PL2-1 and PL2-3)

TSI 3-C specification

Specification  
Principal application Hard-wired probing systems with HPMA.
Mounting DIN rail mounting
Outputs 1. Probe status (N/O or N/C)
2. Position confirm signals (machine ready and arm ready)
Output signal format - voltage free SSR

Probe status N/C or N/O, MRO and  ARO N/O

Maximum current 40 mA

Maximum voltage 30 V

Outputs are protected by fuses (TE5) (f) 50mA

Other I/O Can be connected to either a standard single wire probe input or the four wire alternative.
Select any one output for single wire probe input or utilise all four inputs/outputs for four wire probe inputs.
Power supply

Interface voltage supply (1, 13, 25) 18 V - 30 V dc, Imax = 100 mA not including output loading.
Motor voltage supply (10, 22, 11, 23) 24 V dc + 20% - 10%, Imax + 2.5 A for 4 s (worst case stall). Overcurrent and reverse connection protected.
Self-resettable

TTL compatibility Not compatible
Inputs 1. Inhibit, Arm ready, Machine ready
2. Probe Select inputs2. Probe select inputs
Input signal format 1. Internally pulled down (2k4) ACTIVE HIGH
2. Internally pulled down (2k4) ACTIVE HIGH
Probe vibration filter A trigger delay circuit (6.5ms) can be activated by reversing the brown and white wire connections to the TSI 3 (PL2-1 and PL2-3)

お問い合わせ

詳細価格についてのお問い合わせは、オンラインでお寄せ下さい。直接コンタクトをご希望の場合は、 現地レニショーオフィスまでご連絡ください。